You can use the ASU command line to
show the IMM system
event log for the remote system.
Command syntax
asu immapp showsel [command options] [connection options]
Command
Table 1. OptionsOption |
Description |
--help |
Display help information for commands and exit
without running the command. |
Table 2. Connection optionsConnection option |
Description |
--host<ip> |
Address of the IMM server to operate
on. |
--user<userid> |
IMM user
name to authenticate. The default is USERID. |
--password<password> |
IMM password
to authenticate. The default is PASSWORD. |
--kcs |
Force the use of IPMI over the KCS local interface. |
Command example
C:\asu>asu.exe immapp showsel --host 10.10.10.1 --user USERID --password PASSW0RD
Lenovo Advanced Settings Utility version 10.0.87F
Licensed Materials - Property of Lenovo
(C) Copyright Lenovo Corp. 2007-20nn All Rights Reserved
Connected to IMM at IP address:10.10.10.1
SEL Information
Version : 1.5 (v1.5, v2 compliant)
Entries : 512
Free Space : 0 bytes
Percent Used : 100%
Last Add Time : 02/26/2002 08:58:55
Last Del Time : 02/19/2002 03:43:34
Overflow : true
Supported Cmds : 'Reserve'
1 | 07/03/2012 | 09:38:35 | Event Logging Disabled #0xb6 | Log area reset/cle
ared | Asserted
2 | 07/03/2012 | 09:39:54 | System Firmware Progress #0xb4 | System boot init
iated | Asserted
3 | 07/04/2012 | 07:00:27 | Power Unit #0x01 | Power off/down | Asserted
4 | 07/04/2012 | 07:01:25 | Power Unit #0x01 | Power off/down | Deasserted
5 | 07/04/2012 | 07:01:25 | System Firmware Progress #0xb4 | Unspecified | As
serted
6 | 07/04/2012 | 07:03:21 | System Firmware Progress #0xb4 | System boot init
iated | Asserted
7 | 07/04/2012 | 07:24:06 | Power Unit #0x01 | Power off/down | Asserted
8 | 07/04/2012 | 07:35:48 | Power Unit #0x01 | Power off/down | Deasserted
9 | 07/04/2012 | 07:35:59 | System Firmware Progress #0xb4 | Unspecified | As
serted
10 | 07/04/2012 | 07:38:06 | System Firmware Progress #0xb4 | System boot init
iated | Asserted