Before you can manage a certificate on IMM, you must disable
the HTTPS server, the Lenovo Systems Director, and
the SSL Client Configuration for the LDAP client.
- Before using HTTPS Server Certificate Management, disable
the HTTPS server:
- On a command line, check to see if the IMM HTTPS server configuration
for the web server is disabled. Enter the command:asu show
IMM.SSL_Server_Enable .
The following
output is displayed: IMM.SSL_Server_Enable=Disabled.
- If the server is enabled, disable the IMM HTTPS server configuration
for the web server by using the command: asu set IMM.SSL_Server_Enable
Disabled.
The following output is displayed: IMM.SSL_Server_Enable=Disabled.
- Restart the IMM to
enforce the change (either enable or disable) by entering the asu
rebootimm command.
- Before using Lenovo Systems Director over
HTTPS Certificate Management, disable the director over the HTTPS
server:
- On a command line, enter the asu show IMM.
CIMXMLOverHTTPS_Enable command to see if the Lenovo Systems Director Over
HTTPS is disabled.
The following output is displayed: IMM.CIMXMLOverHTTPS_Enable=Disabled.
- If the server is enabled, disable Lenovo Systems Director Over
HTTPS by using the asu set IMM.CIMXMLOverHTTPS_Enable Disabled command.
The following output is displayed: IMM.CIMXMLOverHTTPS_Enable=Disabled.
- Restart the IMM to
enforce the change (either enable or disable) by entering the asu
rebootimm command.
- Before using SSL Client Certificate Management, disable
the SSL Client Configuration for the LDAP client:
- On a command line, check to see if the SSL Client Configuration
for LDAP client is disabled by entering the asu show IMM.SSL_Client_Enable command.
The following output is displayed: IMM.IMM.SSL_Client_Enable=Disabled.
- If the server is enabled, disable the IMM SSL Client Configuration
for LDAP by using the asu set IMM.SSL_Client_Enable Disabled command.
The following output is displayed: IMM.SSL_Client_Enable=Disabled.