rebootrsa command

Use the rebootrsa command to restart the Remote Supervisor Adapter and Remote Supervisor Adapter II. This command is for BIOS-based servers only.

This command is useful because you must restart a Remote Supervisor Adapter or Remote Supervisor Adapter II after you make changes to the Remote Supervisor Adapter settings. This command takes approximately 30 seconds to complete.

Syntax

The syntax of the rebootrsa command is
asu rebootrsa [-nx]
Note: If the optional -nx parameter is specified, the ASU performs the operation for node x, where x is the selected node in a multi-node system. Node x can be a number from 1 through 8. If the -nx parameter is not specified, the operation is performed on the primary node (node 1).

Output

The output of the rebootrsa command is a message that indicates that the restart of the Remote Supervisor Adapter is completed.

The following example shows the rebootrsa command and corresponding output.

Command line:
 asu rebootrsa
Output:
Rebooting RSA/RSA2...done