RAID adapters Read policy Write policy RAID Levels1 Stripe Size (KB)
ServeRAID-B5015
  • ON
  • OFF
[n/a] R1, R5 4, 8, 16, 32, 64, 128, 256, 512, 1024
LSI-IDEal-RAID [n/a] [n/a] R0, R1 32, 64, 128, 256, 512, 1024, 2048, 4096
LSI-MegaRAID-8480 [n/a] [n/a] R0, R1, R10, R5, R50 4, 8, 16, 32, 64, 128
LSI-SAS-1078-IR [n/a] [n/a] R0, R1 [n/a]
LSI-SAS-RAID [n/a] [n/a] R0, R1, R1E [n/a]
LSI-SCSI-RAID [n/a] [n/a] R1 [n/a]
ServeRAID-7t
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
RVOLUME, R0, R1, R10, R5 16, 32, 64
ServeRAID-8i
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
RVOLUME, R0, R1, R10, R1E, R5, R50, R5EE, R6, R60 16, 32, 64, 128, 256, 512, 1024
ServeRAID-8k
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
RVOLUME, R0, R1, R10, R1E, R5, R6 16, 32, 64, 128, 256, 512, 1024
ServeRAID-8k-l
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
RVOLUME, R0, R1, R10 16, 32, 64, 128, 256, 512, 1024
ServeRAID-8s
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
RVOLUME, R0, R1, R10, R1E, R5, R50, R6 16, 32, 64, 128, 256, 512, 1024
ServeRAID-BR10ie [n/a] [n/a] R0, R1, R1E [n/a]
ServeRAID-BR10il [n/a] [n/a] R0, R1, R1E [n/a]
ServeRAID-M1015 [n/a] [n/a] R0, R1, R10 8, 16, 32, 64
ServeRAID-M1015–R5 [n/a] [n/a] R0, R1, R10, R5, R50 8, 16, 32, 64
ServeRAID-M1xxx [n/a] [n/a] R0, R1, R10 8, 16, 32, 64
ServeRAID-M1xxx_R5 [n/a] [n/a] R0, R1, R10, R5, R50 8, 16, 32, 64
ServeRAID-M5014
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50 8, 16, 32, 64, 128
ServeRAID-M5014-R6-R60
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50, R6, R60 8, 16, 32, 64, 128
ServeRAID-M5015
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50 8, 16, 32, 64, 128
ServeRAID-M5015-R6-R60
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50, R6, R60 8, 16, 32, 64, 128
ServeRAID-M5025
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50 8, 16, 32, 64, 128, 256, 512, 1024
ServeRAID-M5025-R6-R60
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50, R6, R60 8, 16, 32, 64, 128, 256, 512, 1024
ServeRAID-M5xxx
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50, R6, R60 8, 16, 32, 64, 128, 256, 512, 1024
ServeRAID-M51xx
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10 8, 16, 32, 64, 128, 256, 512, 1024
ServeRAID-M51xx_R5
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50 8, 16, 32, 64, 128, 256, 512, 1024
ServeRAID-M51xx_R6
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R6, R60 8, 16, 32, 64, 128, 256, 512, 1024
ServeRAID-M51xx_R5_R6
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50, R6, R60 8, 16, 32, 64, 128, 256, 512, 1024
ServeRAID-M5210
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0,R1,R10 8,16.32,64
ServeRAID-M5210-R5
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50, R6, R60 8,16.32,64
ServeRAID-M1215
  • ON
  • OFF
  • AUTO
  • Write
  • ON
  • OFF
R0, R1, R10 64
ServeRAID-M1215-R5
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50 64
ServeRAID-M1210e
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10 64
ServeRAID-MR10i
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50, R6, R60 8, 16, 32, 64, 128
ServeRAID-MR10il
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50, R6, R60 8, 16, 32, 64, 128
ServeRAID-MR10is
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50, R6, R60 8, 16, 32, 64, 128, 256, 512, 1024
ServeRAID-MR10k
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50, R6, R60 16, 32, 64, 128, 256, 512, 1024
ServeRAID-MR10M
  • ON
  • OFF
  • AUTO
  • ON
  • OFF
R0, R1, R10, R5, R50, R6, R60 8, 16, 32, 64, 128
ServeRAID-C100 [n/a] [n/a] R0, R1, R10 64
ServeRAID-C100-R5 [n/a] [n/a] R0, R1, R10, R5 64
ServeRAID-C105 [n/a] [n/a] R0, R1,R10 64
SAS2004 [n/a] [n/a] R0, R1, R10, R1E [n/a]
  1. RAID levels 5E and 5EE support only one logical drive per array.

Default RAID levels are described in Default RAID levels.