The default RAID level that is applied to a logical drive depends
on the number of drives in the array and the controller type. These
default values are designed to match the default values of the express
configuration method in ServeRAID Manager where applicable. The following
table shows the default RAID values that PRAID uses when
AUTO is
specified for
raidlevel.
Table 1. Default RAID levels |
Drives in array |
Controller |
1 |
2 |
3 |
4 |
5 or more |
ServeRAID-B5015 |
[n/a] |
RAID 1 |
RAID 5 |
RAID 5+Hotspare |
RAID 5+Hotspare |
LSI-IDEal-RAID |
[n/a] |
RAID 1 |
[n/a] |
[n/a] |
[n/a] |
LSI-MegaRAID-8480 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0+Hotspare |
RAID 0+Hotspare |
LSI-SAS-1078-IR |
[n/a] |
RAID 1 |
RAID 1+Hotspare |
RAID 1+Hotspare |
RAID 1+Hotspare |
LSI-SAS-RAID |
[n/a] |
RAID 1 |
RAID 1E+Hotspare |
RAID 1E+Hotspare |
RAID 1E+Hotspare |
LSI-SCSI-RAID |
[n/a] |
RAID 1 |
RAID 1+Hotspare |
RAID 1+Hotspare |
RAID 1+Hotspare |
ServeRAID-7t |
RAID 0 |
RAID 1 |
RAID 5 |
RAID 5+Hotspare |
RAID 5+Hotspare |
ServeRAID-8i |
VOLUME |
RAID 1 |
RAID 5 |
RAID 5+Hotspare |
RAID 5+Hotspare |
ServeRAID-8k |
VOLUME |
RAID 1 |
RAID 5 |
RAID 5+Hotspare |
RAID 5+Hotspare |
ServeRAID-8k-l |
VOLUME |
RAID 1 |
RAID 1+Hotspare |
RAID 10 |
RAID 10+Hotspare |
ServeRAID-8s |
VOLUME |
RAID 1 |
RAID 5 |
RAID 5+Hotspare |
RAID 5+Hotspare |
ServeRAID-BR10ie |
[n/a] |
RAID 1 |
RAID IE |
RAID IE + Hotspare |
RAID IE + Hotspare |
ServeRAID-BR10il |
[n/a] |
RAID 1 |
RAID IE |
RAID IE + Hotspare |
RAID IE + Hotspare |
ServeRAID-M1015 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M1015–R5 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M1xxx |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M1xxx_R5 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M5014 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M5014-R6-R60 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M5015 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M5015-R6-R60 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M5025 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M5025-R6-R60 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M5xxx |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M51xx |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M51xx_R5 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M51xx_R6 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M51xx_R5_R6 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M5210 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M5210-R5 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M1215 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M1215-R5 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-M1210e |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-MR10i |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-MR10il |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-MR10is |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-MR10k |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-MR10M |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-C100 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-C100-R5 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
ServeRAID-C105 |
RAID 0 |
RAID 0 |
RAID 0 |
RAID 0 + Hotspare |
RAID 0 + Hotspare |
SAS2004 |
[n/a] |
RAID 0 |
RAID 0 |
RAID 10 |
RAID 10 |