The default RAID level that is applied to a logical drive depends on the number of drives in the array and the controller type. These default values are designed to match the default values of the express configuration method in ServeRAID Manager where applicable.
Drives in array | |||||
---|---|---|---|---|---|
Controller | 1 | 2 | 3 | 4 | 5 or more |
ServeRAID-B5015 | [n/a] | RAID 1 | RAID 5 | RAID 5+Hotspare | RAID 5+Hotspare |
LSI-IDEal-RAID | [n/a] | RAID 1 | [n/a] | [n/a] | [n/a] |
LSI-MegaRAID-8480 | RAID 0 | RAID 0 | RAID 0 | RAID 0+Hotspare | RAID 0+Hotspare |
LSI-SAS-1078-IR | [n/a] | RAID 1 | RAID 1+Hotspare | RAID 1+Hotspare | RAID 1+Hotspare |
LSI-SAS-RAID | [n/a] | RAID 1 | RAID 1E+Hotspare | RAID 1E+Hotspare | RAID 1E+Hotspare |
LSI-SCSI-RAID | [n/a] | RAID 1 | RAID 1+Hotspare | RAID 1+Hotspare | RAID 1+Hotspare |
ServeRAID-7t | RAID 0 | RAID 1 | RAID 5 | RAID 5+Hotspare | RAID 5+Hotspare |
ServeRAID-8i | VOLUME | RAID 1 | RAID 5 | RAID 5+Hotspare | RAID 5+Hotspare |
ServeRAID-8k | VOLUME | RAID 1 | RAID 5 | RAID 5+Hotspare | RAID 5+Hotspare |
ServeRAID-8k-l | VOLUME | RAID 1 | RAID 1+Hotspare | RAID 10 | RAID 10+Hotspare |
ServeRAID-8s | VOLUME | RAID 1 | RAID 5 | RAID 5+Hotspare | RAID 5+Hotspare |
ServeRAID-BR10ie | [n/a] | RAID 1 | RAID IE | RAID IE + Hotspare | RAID IE + Hotspare |
ServeRAID-BR10il | [n/a] | RAID 1 | RAID IE | RAID IE + Hotspare | RAID IE + Hotspare |
ServeRAID-M1015 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M1015R5 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M1xxx | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M1xxx_R5 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M5014 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M5014-R6-R60 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M5015 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M5015-R6-R60 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M5025 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M5025-R6-R60 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M5xxx | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M51xx | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M51xx_R5 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M51xx_R6 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M51xx_R5_R6 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M5210 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M5210-R5 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M5215 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M1215 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M1215-R5 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-M1210e | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-MR10i | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-MR10il | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-MR10is | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-MR10k | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-MR10M | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-C100 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-C100-R5 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
ServeRAID-C105 | RAID 0 | RAID 0 | RAID 0 | RAID 0 + Hotspare | RAID 0 + Hotspare |
SAS2004 | [n/a] | RAID 0 | RAID 0 | RAID 10 | RAID 10 |