This topic shows deploy mode, capture mode, and restore-defaults
mode examples.
Deploy mode examples
PRAID /r /d /y
- Uses default settings to configure all RAID controllers in the
system
- Does not prompt before setting controllers to factory-default
settings
- When required, performs drive synchronization without prompting
The following example is useful for unattended scripted installations.
PRAID /f:policies.ini /r /v:5 /e1
- Uses the policies file, policies.ini, to
configure the RAID controllers in the system
- Sets the verbose mode to maximum
- Returns an error code if there were no matching policies for one
or more controllers
Capture mode examples
PRAID /c /f:c:\mydata\policies.ini
Captures
the configuration of all RAID controllers into the file: C:\mydata\policies.ini.
PRAID /c:m,t /f:policies.ini
- Captures the configuration of all RAID controllers into the file policies.ini
- Uses the system machine type and RAID controller type as the AppliesTo.1 entry
in the policies file for each captured configuration
Restore-defaults mode examples
PRAID /r /v:0 /y
- Restores all RAID controllers to factory-default settings.
- Operates in silent mode; no messages are printed to the screen.
- Does not prompt the user before restoring factory-default settings.