Use the rebootimm command to reboot IMM manually. This is similar to the flash command --noreboot parameter, which specifies that ToolsCenter Suite CLI will not reboot IMM after flashing firmware.
rebootimm command syntax
OneCli.exe misc rebootimm [--imm <userid:password@IP[:port]>]
Parameter | Required/Optional | Notes |
---|---|---|
--imm | Optional |
Note: Both IPv4 and IPv6 addresses are supported.
Enclose IPv6 addresses in brackets. For example, [FE80::3BA7:94FF:FE07:CBD0]. If the IPv6 is LLA (Link Local IPV6), the format is [FE80::3BA7:94FF:FE07:CBD0%xxx]. Replace xxx with the name of the interface through which
either the service processor or the sftp server (for the --sftp argument)
can be reached on the local network of the OS on which the ToolsCenter
Suite CLI runs.
|
Example of the rebootimm command
OneCli.exe misc rebootimm --imm USERID:PASSW0RD@10.240.252.102[:5989]
Lenovo ToolsCenterSuite CLI tcliXXX-X.X.X
Based on module version X.X.X
Licensed Materials - Property of Lenovo
(C) Copyright Lenovo Corp. 2013-2016 All Rights Reserved
Invoking SHOW command ...
Connected to IMM by IP address 10.240.252.102
Issue the reboot command to IMM
IMM is rebooting now
Waiting 4 minutes to check.
Successfully reboot IMM.