loaddefault command

Use the loaddefault command to load the default values of one or more settings.

loaddefault command syntax

OneCli.exe config loaddefault[command option][--output<folder>][connection option]
Table 1. loaddefault command parameters
Parameter Required/Optional Notes
command option Optional
all
Default value.
Displays all of the supported settings.
group name
Displays the settings that belong to a group name.
setting name
The setting name value.
output Optional

By default, the log file output is saved to: ../Onecli-%PID%-%date%-%time%/.

connection option Optional
--imm <user:pwd@ip>
Use for OOB.
Use for in-band, if you know the LAN over USB IP of the target IMM.
Use to specify the target IMM.
--node <x>
Use for inband cases on a multinode system.
Where x is a numeric value that indicates the node number. For example, if "--node 2" the target IMM is in the second node of a multinode system.

Example of the loaddefault command

OneCli.exe config loaddefault BootModes.SystemBootMode
This is the output generated from this example:
Lenovo ToolsCenterSuite CLI tcliXXX-X.X.X
Based on module version X.X.X
Licensed Materials - Property of Lenovo
(C) Copyright Lenovo Corp. 2013-2016 All Rights Reserved
Invoking SHOW command ...
Connected to IMM by IP address 10.240.252.102
BootModes.SystemBootMode=UEFI Mode
Waiting for command completion status.
Command completed successfully.