showdefault command

Use the showdefault command to show the default values of one or more settings.

showdefault command syntax

OneCli.exe config showdefault[command option][--output<folder>][connection option]
Table 1. showdefault command parameters
Parameter Required/Optional Notes
command option Optional
all
Default value.
Displays all of the supported settings.
group name
Displays the settings that belong to a group name.
setting name
The setting name value.
--output Optional

By default, the log file output is saved to: ../Onecli-%PID%-%date%-%time%/.

connection option Optional
--imm <user:pwd@ip>
Use for OOB.
Use for in-band, if you know the LAN over USB IP of the target IMM.
Use to specify the target IMM.
--node <x>
Use for inband cases on a multinode system.
Where x is a numeric value that indicates the node number. For example, if "--node 2" the target IMM is in the second node of a multinode system.
Note: Some settings do not have a default value and will not be included in the list.

Example of the showdefault command

OneCli.exe config showdefault 
This is the output generated from this example:
Lenovo ToolsCenterSuite CLI tcliXXX-X.X.X
Based on module version X.X.X
Licensed Materials - Property of Lenovo
(C) Copyright Lenovo Corp. 2013-2016 All Rights Reserved
Invoking SHOW command ...
Connected to IMM by IP address 10.240.252.102
IMM.SMTP_Authentication=Disabled
IMM.SMTP_UserName=
IMM.SMTP_Password=
IMM.SMTP_AuthMethod=CRAM-MD5
IMM.SMTP_ReversePath=
IMM.Select_LDAP_Servers=Use Pre-Configured LDAP Servers



Processors.CoresinCPUPackage=All
Processors.QPILinkFrequency=Max Performance
Power.Power_ActiveEnergyManager=Capping Enabled
Power.PowerPerformanceBias=Platform Controlled
Power.PlatformControlledType=Efficiency - Favor Performance
Power.WorkloadConfiguration=Balanced
DevicesandIOPorts.ActiveVideo=Onboard Device
DevicesandIOPorts.PCI64-BitResourceAllocation=Enable
DevicesandIOPorts.MMConfigBase=Auto
DevicesandIOPorts.IntelVTforDirectedIOVT-d=Enable
DevicesandIOPorts.COMPort1=Enable